import logging
from pathlib import Path
from queue import Empty
import time
import pytest
import config
from control_runtime import (
ControlWorker,
build_open_loop_points,
load_model,
validate_device_settings,
validate_opening,
validate_open_loop_settings,
validate_target,
)
class FakeHardware:
def __init__(self, *, connect_ok=True):
self.connect_ok = connect_ok
self.connected = False
self.disconnect_count = 0
self.motor_commands = []
def connect(self):
self.connected = self.connect_ok
return self.connect_ok
def disconnect(self):
self.connected = False
self.disconnect_count += 1
def get_flow(self, _address):
return 20.0
def get_pressure(self, address):
if address == config.PRESSURE_BEFORE_ADDR:
return 200.0
return 100.0
def set_motor_position(self, position, channel=None):
self.motor_commands.append((float(position), channel))
return True
class OverpressureHardware(FakeHardware):
def get_pressure(self, address):
if address == config.PRESSURE_BEFORE_ADDR:
return config.MAX_PRESSURE_KPA + 1.0
return 100.0
class MemoryOpenLoopRecorder:
def __init__(self):
self.csv_path = Path("memory_open_loop.csv")
self.image_path = Path("memory_open_loop.png")
self.sample_count = 0
self.rows = []
self.finalize_count = 0
def record(self, **row):
self.rows.append(row)
self.sample_count += 1
def finalize(self):
self.finalize_count += 1
return self.image_path if self.sample_count else None
def close(self):
pass
def wait_for_event(worker, predicate, timeout=2.0):
deadline = time.monotonic() + timeout
while time.monotonic() < deadline:
try:
event = worker.events.get(timeout=0.1)
except Empty:
continue
if predicate(event):
return event
raise AssertionError("等待后台线程事件超时")
def make_logger():
logger = logging.getLogger(f"test-control-runtime-{time.monotonic_ns()}")
logger.addHandler(logging.NullHandler())
return logger
def test_validate_ui_values():
settings = validate_device_settings(" 192.168.1.88 ", "502", "1")
assert settings.host == "192.168.1.88"
assert settings.port == 502
assert settings.slave_id == 1
assert validate_target("50.5") == 50.5
assert validate_opening("25.5") == 25.5
with pytest.raises(ValueError, match="0100"):
validate_opening("100.1")
def test_builtin_model_is_valve_model_004():
info = load_model()
assert info.is_builtin is True
assert info.path.name == "valve_model_004.json"
assert info.point_count == 80
assert info.model.motor_open == config.MOTOR_OPEN_POSITION
assert info.model.motor_closed == config.MOTOR_CLOSED_POSITION
def test_validate_and_build_gui_open_loop_points():
settings = validate_open_loop_settings(
min_opening_pct="0",
max_opening_pct="10",
opening_step_pct="5",
random_seed="42",
include_fine_scan=False,
)
points = build_open_loop_points(settings)
assert sorted(opening for opening, _position in points) == [0.0, 5.0, 10.0]
assert all(
config.MOTOR_OPEN_POSITION <= position <= config.MOTOR_CLOSED_POSITION
for _opening, position in points
)
with pytest.raises(ValueError, match="开度范围"):
validate_open_loop_settings(
min_opening_pct=50,
max_opening_pct=50,
include_fine_scan=False,
)
def test_worker_connect_control_and_safe_disconnect():
hardware = FakeHardware()
worker = ControlWorker(make_logger(), hardware_factory=lambda _settings: hardware)
worker.start()
wait_for_event(
worker,
lambda event: event.get("kind") == "state"
and event.get("state") == "DISCONNECTED",
)
settings = validate_device_settings("192.168.1.88", 502, 1)
worker.request_connect(settings)
wait_for_event(
worker,
lambda event: event.get("kind") == "state"
and event.get("state") == "MONITORING",
)
assert hardware.connected is True
assert hardware.motor_commands[0] == (
config.MOTOR_OPEN_POSITION,
config.MOTOR_OUTPUT_ADDR,
)
worker.request_target(50.0)
wait_for_event(
worker,
lambda event: event.get("kind") == "target_applied",
)
telemetry = wait_for_event(
worker,
lambda event: event.get("kind") == "telemetry"
and event.get("target_flow_slm") == 50.0,
)
assert telemetry["measured_flow_slm"] == 20.0
assert 0.0 <= telemetry["opening_pct"] <= 100.0
assert telemetry["pid_mode"] in {"FAR", "NEAR"}
worker.request_disconnect()
wait_for_event(
worker,
lambda event: event.get("kind") == "state"
and event.get("state") == "DISCONNECTED",
)
assert hardware.connected is False
assert hardware.motor_commands[-1] == (
config.MOTOR_OPEN_POSITION,
config.MOTOR_OUTPUT_ADDR,
)
assert hardware.disconnect_count == 1
worker.request_shutdown()
wait_for_event(worker, lambda event: event.get("kind") == "shutdown_complete")
worker.thread.join(timeout=1.0)
assert not worker.is_alive()
def test_worker_runs_open_loop_scan_and_keeps_connection():
hardware = FakeHardware()
recorder = MemoryOpenLoopRecorder()
worker = ControlWorker(
make_logger(),
hardware_factory=lambda _settings: hardware,
open_loop_recorder_factory=lambda: recorder,
)
worker.start()
wait_for_event(worker, lambda event: event.get("state") == "DISCONNECTED")
worker.request_connect(validate_device_settings("192.168.1.88", 502, 1))
wait_for_event(worker, lambda event: event.get("state") == "MONITORING")
settings = validate_open_loop_settings(
min_opening_pct=0,
max_opening_pct=1,
opening_step_pct=1,
random_seed=1,
sample_period_s=0.005,
steady_window_s=0.01,
max_wait_s=0.03,
include_fine_scan=False,
)
worker.request_open_loop_start(settings)
started = wait_for_event(
worker, lambda event: event.get("kind") == "open_loop_started"
)
assert started["total_steps"] == 2
finished = wait_for_event(
worker, lambda event: event.get("kind") == "open_loop_finished"
)
assert finished["completed"] is True
assert finished["sample_count"] == recorder.sample_count
assert recorder.sample_count >= 4
assert recorder.finalize_count == 1
wait_for_event(worker, lambda event: event.get("state") == "MONITORING")
assert hardware.connected is True
assert hardware.motor_commands[-1] == (
config.MOTOR_OPEN_POSITION,
config.MOTOR_OUTPUT_ADDR,
)
worker.request_shutdown()
wait_for_event(worker, lambda event: event.get("kind") == "shutdown_complete")
worker.thread.join(timeout=1.0)
assert not worker.is_alive()
def test_worker_stops_closed_loop_at_full_open_and_accepts_manual_opening():
hardware = FakeHardware()
worker = ControlWorker(make_logger(), hardware_factory=lambda _settings: hardware)
worker.start()
wait_for_event(worker, lambda event: event.get("state") == "DISCONNECTED")
worker.request_connect(validate_device_settings("192.168.1.88", 502, 1))
wait_for_event(worker, lambda event: event.get("state") == "MONITORING")
worker.request_target(50.0)
wait_for_event(worker, lambda event: event.get("kind") == "target_applied")
worker.request_manual_opening(25.0)
warning = wait_for_event(
worker,
lambda event: event.get("kind") == "warning"
and "先停止流量控制" in event.get("message", ""),
)
assert "先停止流量控制" in warning["message"]
worker.request_stop_control()
stopped = wait_for_event(
worker, lambda event: event.get("kind") == "control_stopped"
)
assert stopped["opening_pct"] == 100.0
assert stopped["motor_position"] == config.MOTOR_OPEN_POSITION
wait_for_event(worker, lambda event: event.get("state") == "MONITORING")
assert hardware.motor_commands[-1] == (
config.MOTOR_OPEN_POSITION,
config.MOTOR_OUTPUT_ADDR,
)
worker.request_manual_opening(25.0)
manual = wait_for_event(
worker, lambda event: event.get("kind") == "manual_opening_applied"
)
assert manual["opening_pct"] == 25.0
assert manual["motor_position"] == pytest.approx(950.0)
wait_for_event(
worker,
lambda event: event.get("kind") == "telemetry"
and event.get("pid_mode") == "未启用",
)
assert hardware.motor_commands[-1] == (950.0, config.MOTOR_OUTPUT_ADDR)
worker.request_shutdown()
wait_for_event(worker, lambda event: event.get("kind") == "shutdown_complete")
worker.thread.join(timeout=1.0)
assert not worker.is_alive()
def test_disconnect_during_open_loop_finalizes_partial_data():
hardware = FakeHardware()
recorder = MemoryOpenLoopRecorder()
worker = ControlWorker(
make_logger(),
hardware_factory=lambda _settings: hardware,
open_loop_recorder_factory=lambda: recorder,
)
worker.start()
wait_for_event(worker, lambda event: event.get("state") == "DISCONNECTED")
worker.request_connect(validate_device_settings("192.168.1.88", 502, 1))
wait_for_event(worker, lambda event: event.get("state") == "MONITORING")
settings = validate_open_loop_settings(
min_opening_pct=0,
max_opening_pct=100,
opening_step_pct=1,
sample_period_s=0.02,
steady_window_s=1,
max_wait_s=1,
include_fine_scan=False,
)
worker.request_open_loop_start(settings)
wait_for_event(worker, lambda event: event.get("kind") == "open_loop_started")
worker.request_disconnect()
finished = wait_for_event(
worker, lambda event: event.get("kind") == "open_loop_finished"
)
assert finished["completed"] is False
assert finished["reason"] == "设备断开或程序退出"
assert recorder.finalize_count == 1
wait_for_event(worker, lambda event: event.get("state") == "DISCONNECTED")
assert hardware.connected is False
worker.request_shutdown()
wait_for_event(worker, lambda event: event.get("kind") == "shutdown_complete")
worker.thread.join(timeout=1.0)
assert not worker.is_alive()
def test_worker_connection_failure_reports_fault_without_hardware_access():
hardware = FakeHardware(connect_ok=False)
worker = ControlWorker(make_logger(), hardware_factory=lambda _settings: hardware)
worker.start()
wait_for_event(worker, lambda event: event.get("state") == "DISCONNECTED")
worker.request_connect(validate_device_settings("192.168.1.88", 502, 1))
fault = wait_for_event(worker, lambda event: event.get("kind") == "fault")
assert "无法连接 PLC" in fault["message"]
assert hardware.motor_commands == []
assert hardware.disconnect_count == 1
worker.request_shutdown()
wait_for_event(worker, lambda event: event.get("kind") == "shutdown_complete")
worker.thread.join(timeout=1.0)
assert not worker.is_alive()
def test_monitoring_stage_overpressure_triggers_safe_disconnect():
hardware = OverpressureHardware()
worker = ControlWorker(make_logger(), hardware_factory=lambda _settings: hardware)
worker.start()
wait_for_event(worker, lambda event: event.get("state") == "DISCONNECTED")
worker.request_connect(validate_device_settings("192.168.1.88", 502, 1))
wait_for_event(worker, lambda event: event.get("state") == "MONITORING")
fault = wait_for_event(worker, lambda event: event.get("kind") == "fault")
assert "超过上限" in fault["message"]
assert hardware.connected is False
assert hardware.motor_commands[-1][0] == config.MOTOR_OPEN_POSITION
worker.request_shutdown()
wait_for_event(worker, lambda event: event.get("kind") == "shutdown_complete")
worker.thread.join(timeout=1.0)
assert not worker.is_alive()