"""气体流量闭环控制程序入口。
示例:
python main.py --target 50
程序启动后直接从当前阀门开度(默认全开)开始闭环。Ctrl+C、控制故障或
其他异常会断开 MT2-AM8;阀门不被驱动时默认回到全开。
"""
import argparse
import logging
from pathlib import Path
import sys
import time
try:
import msvcrt # Windows 专用:非阻塞键盘输入,用于运行中切换目标流量
except ImportError: # 非 Windows 平台无此模块,退化为仅周期控制
msvcrt = None
import config
from controllers import IncrementalPID
from data_logger import FlowRunRecorder
from flow_control import FlowControlFault, FlowControlLoop
from performance_reporter import PerformanceReporter
class ConsoleGate(logging.Filter):
"""终端输出闸门:输入模式下挡住终端日志,文件日志不受影响。"""
def __init__(self):
super().__init__()
self.blocked = False
def filter(self, _record):
return not self.blocked
def build_logger():
log_dir = Path(__file__).resolve().parent / config.LOG_DIRECTORY
log_dir.mkdir(parents=True, exist_ok=True)
log_path = log_dir / config.LOG_FILE_NAME
logger = logging.getLogger("flow_control")
logger.setLevel(logging.INFO)
logger.handlers.clear()
formatter = logging.Formatter(
"%(asctime)s.%(msecs)03d %(levelname)s %(message)s",
datefmt="%Y-%m-%d %H:%M:%S",
)
file_handler = logging.FileHandler(log_path, encoding="utf-8")
file_handler.setFormatter(formatter)
logger.addHandler(file_handler)
console_handler = logging.StreamHandler()
console_handler.setFormatter(formatter)
console_gate = ConsoleGate()
console_handler.addFilter(console_gate)
logger.addHandler(console_handler)
return logger, console_gate
def build_control_loop(hardware, logger):
pid = IncrementalPID(
kp=config.PID_FAR_KP,
ki=config.PID_FAR_KI,
kd=config.PID_FAR_KD,
dt=config.CONTROL_PERIOD_S,
out_min=config.OPENING_MIN_PCT,
out_max=config.OPENING_MAX_PCT,
output_rate_limit=config.MAX_OPENING_RATE_FAR_PCT_S,
)
return FlowControlLoop(
hardware=hardware,
pid=pid,
period_s=config.CONTROL_PERIOD_S,
flow_channel=config.FLOW_INPUT_CHANNEL,
pressure_channel=config.PRESSURE_INPUT_CHANNEL,
motor_channel=config.MOTOR_OUTPUT_CHANNEL,
motor_open_position=config.MOTOR_OPEN_POSITION,
motor_closed_position=config.MOTOR_CLOSED_POSITION,
target_min_slm=config.TARGET_FLOW_MIN_SLM,
target_max_slm=config.TARGET_FLOW_MAX_SLM,
zero_flow_threshold_slm=config.ZERO_FLOW_THRESHOLD_SLM,
flow_valid_min_slm=config.FLOW_VALID_MIN_SLM,
flow_valid_max_slm=config.FLOW_VALID_MAX_SLM,
max_pressure_kpa=config.MAX_PRESSURE_KPA,
max_control_dt_s=config.MAX_CONTROL_DT_S,
max_consecutive_flow_failures=config.MAX_CONSECUTIVE_FLOW_FAILURES,
max_consecutive_pressure_failures=(
config.MAX_CONSECUTIVE_PRESSURE_FAILURES
),
pid_far_gains=(
config.PID_FAR_KP,
config.PID_FAR_KI,
config.PID_FAR_KD,
),
pid_near_gains=(
config.PID_NEAR_KP,
config.PID_NEAR_KI,
config.PID_NEAR_KD,
),
opening_rate_far_pct_s=config.MAX_OPENING_RATE_FAR_PCT_S,
opening_rate_near_pct_s=config.MAX_OPENING_RATE_NEAR_PCT_S,
pid_near_error_min_slm=config.PID_NEAR_ERROR_MIN_SLM,
pid_near_error_target_ratio=(
config.PID_NEAR_ERROR_TARGET_RATIO
),
pid_far_error_min_slm=config.PID_FAR_ERROR_MIN_SLM,
pid_far_error_target_ratio=config.PID_FAR_ERROR_TARGET_RATIO,
pid_mode_switch_confirm_cycles=(
config.PID_MODE_SWITCH_CONFIRM_CYCLES
),
logger=logger,
)
def parse_args(argv=None):
parser = argparse.ArgumentParser(description="MT2-AM8 气体流量 PID 控制")
parser.add_argument(
"--target",
type=float,
required=True,
help=(
"目标流量 SLM,允许范围 "
f"{config.TARGET_FLOW_MIN_SLM}~{config.TARGET_FLOW_MAX_SLM}"
),
)
return parser.parse_args(argv)
def format_status(result):
flow_text = (
"--" if result.measured_flow_slm is None
else f"{result.measured_flow_slm:.2f}"
)
pressure_text = (
"--" if result.pressure_kpa is None
else f"{result.pressure_kpa:.2f}"
)
return (
f"状态={result.status} 目标={result.target_flow_slm:.2f} SLM "
f"实际={flow_text} SLM 压力={pressure_text} kPa "
f"开度={result.opening_pct:.2f}% "
f"行程={result.motor_position:.1f} dt={result.actual_dt_s:.3f}s"
)
def run(target_flow_slm):
config.validate_config()
logger, console_gate = build_logger()
try:
from PcControl import MT2AM8Client
except ModuleNotFoundError as exc:
if exc.name and exc.name.startswith("pymodbus"):
logger.critical(
"缺少 PcControl.py 所需的 pymodbus;请在运行本工程的 Python "
"环境中安装与现有硬件代码兼容的 pymodbus 版本"
)
return 6
raise
hardware = MT2AM8Client(
host=config.MT2AM8_HOST,
port=config.MT2AM8_PORT,
slave_id=config.MT2AM8_SLAVE_ID,
pressure_range=config.PRESSURE_RANGE_KPA,
flow_range=config.FLOW_METER_RANGE_SLM,
)
controller = build_control_loop(hardware, logger)
controller.set_target_flow(target_flow_slm)
connected = False
recorder = None
reporter = None
exit_code = 0
try:
logger.info(
"正在连接 MT2-AM8 %s:%s,目标流量=%.3f SLM",
config.MT2AM8_HOST,
config.MT2AM8_PORT,
target_flow_slm,
)
connected = bool(hardware.connect())
if not connected:
raise FlowControlFault(
"DEVICE_CONNECT_FAILED",
"STARTUP",
"无法连接 MT2-AM8",
{
"host": config.MT2AM8_HOST,
"port": config.MT2AM8_PORT,
"slave_id": config.MT2AM8_SLAVE_ID,
},
)
# 控制前读取一次当前流量,作为超调量方向的基准。
try:
initial_flow_slm = hardware.get_flow(config.FLOW_INPUT_CHANNEL)
except Exception:
initial_flow_slm = None
reporter = PerformanceReporter(
controller.pid,
window_s=config.STEADY_STATE_WINDOW_S,
sample_period_s=config.CONTROL_PERIOD_S,
band_pct=config.STEADY_STATE_BAND_PCT,
std_pct=config.STEADY_STATE_STD_PCT,
flow_range_min_slm=config.TARGET_FLOW_MIN_SLM,
flow_range_max_slm=config.TARGET_FLOW_MAX_SLM,
initial_flow_slm=initial_flow_slm,
logger=logger,
)
controller.start(initial_opening=config.INITIAL_OPENING_PCT)
recorder = FlowRunRecorder(
Path(__file__).resolve().parent / config.DATA_DIRECTORY,
plot_dpi=config.PLOT_DPI,
)
logger.info("逐周期数据将保存到 %s", recorder.csv_path)
logger.info(
"闭环控制已启动;按 Ctrl+C 停止,按 %s 切换目标流量",
config.TARGET_SWITCH_KEY.upper(),
)
input_mode = False
input_buf = ""
def apply_target():
"""把输入缓冲区解析为新的目标流量并生效。"""
raw = input_buf.strip()
if not raw:
logger.warning("未输入目标流量,已忽略")
return
try:
value = float(raw)
except ValueError:
logger.warning("无法解析目标流量 %r,已忽略", raw)
return
try:
controller.set_target_flow(value)
except ValueError as exc:
logger.warning("目标流量设置失败:%s", exc)
return
reporter.reset()
logger.info("目标流量已切换为 %.3f SLM", value)
def process_keys():
"""非阻塞处理键盘输入;输入模式下控制循环照常运行。"""
nonlocal input_mode, input_buf
if msvcrt is None:
return
while msvcrt.kbhit():
ch = msvcrt.getch()
if not input_mode:
if ch == b"\x03": # Ctrl+C,交给外层 KeyboardInterrupt 处理
raise KeyboardInterrupt
key = ch.decode("ascii", errors="ignore").lower()
if key == config.TARGET_SWITCH_KEY:
input_mode = True
input_buf = ""
console_gate.blocked = True
print(
f"当前目标={controller.target_flow_slm:.2f} SLM"
f"请输入新目标流量 (回车确认, Esc 取消): ",
end="",
flush=True,
)
else:
if ch in (b"\r", b"\n"):
print()
console_gate.blocked = False
input_mode = False
apply_target()
elif ch == b"\x1b": # Esc 取消
console_gate.blocked = False
input_mode = False
print(" (已取消)")
elif ch in (b"\x08", b"\x7f"): # 退格删除最后一位
if input_buf:
input_buf = input_buf[:-1]
print("\b \b", end="", flush=True)
else:
text = ch.decode("ascii", errors="ignore")
if text and text.isprintable():
input_buf += text
print(text, end="", flush=True)
next_deadline = time.perf_counter()
next_status_time = next_deadline
while True:
now = time.perf_counter()
process_keys()
result = controller.step(now=now)
recorder.record(result)
reporter.observe(result)
if config.AUTO_STOP_ON_STEADY and reporter.steady_reached:
logger.info("已达到稳态,自动停止控制")
break
if now >= next_status_time or result.status != "OK":
logger.info(format_status(result))
next_status_time = now + config.STATUS_PRINT_PERIOD_S
next_deadline += config.CONTROL_PERIOD_S
sleep_s = next_deadline - time.perf_counter()
if sleep_s > 0:
time.sleep(sleep_s)
else:
# 丢弃已经错过的节拍,避免连续快速补跑 PID。
next_deadline = time.perf_counter()
except KeyboardInterrupt:
console_gate.blocked = False
logger.info("收到 Ctrl+C,正在停止控制")
except FlowControlFault as exc:
console_gate.blocked = False
exit_code = 2
logger.critical("控制故障:%s", exc)
except Exception:
console_gate.blocked = False
exit_code = 3
logger.exception("未处理异常,系统将退出")
finally:
console_gate.blocked = False
if connected:
try:
hardware.disconnect()
except Exception:
exit_code = max(exit_code, 5)
logger.exception("断开 MT2-AM8 时发生异常")
if recorder is not None:
try:
image_path = recorder.finalize()
logger.info("控制数据已保存:%s", recorder.csv_path)
if image_path is not None:
logger.info("三联曲线图已保存:%s", image_path)
else:
logger.warning("本次运行没有采样点,因此未生成曲线图")
except Exception:
recorder.close()
exit_code = max(exit_code, 7)
logger.exception("保存控制数据曲线图失败;CSV 数据仍保留")
if reporter is not None:
try:
reporter.finalize()
except Exception:
logger.exception("生成控制性能报告时发生异常")
logger.info("程序结束,退出码=%d", exit_code)
return exit_code
def main(argv=None):
args = parse_args(argv)
return run(args.target)
if __name__ == "__main__":
sys.exit(main())