Files
ReinLoopTest/ReinLoop/tests/test_simulated_device.py
T
2026-07-31 11:29:10 +08:00

41 lines
1.4 KiB
Python

import importlib.util
import time
import unittest
from pathlib import Path
MODULE_PATH = Path(__file__).resolve().parents[1] / "core" / "simulated_device.py"
SPEC = importlib.util.spec_from_file_location("simulated_device_under_test", MODULE_PATH)
SIMULATED = importlib.util.module_from_spec(SPEC)
SPEC.loader.exec_module(SIMULATED)
class SimulatedDeviceTests(unittest.TestCase):
def test_connect_read_and_write_without_hardware(self):
device = SIMULATED.SimulatedDevice()
self.assertTrue(device.connect())
self.assertTrue(device.set_motor_position(0))
self.assertIsInstance(device.get_pressure(), float)
self.assertIsInstance(device.get_flow(), float)
self.assertEqual(len(device.command_log), 1)
device.disconnect()
self.assertFalse(device.connected)
def test_pressure_model_responds_to_valve_position(self):
device = SIMULATED.SimulatedDevice()
device.connect()
device.set_motor_position(0)
time.sleep(0.02)
open_pressure = device.get_pressure()
device.set_motor_position(1000)
time.sleep(0.02)
closed_pressure = device.get_pressure()
self.assertGreaterEqual(open_pressure, 0.0)
self.assertGreaterEqual(closed_pressure, 0.0)
self.assertEqual(device.read_current_position(), 1000.0)
device.disconnect()
if __name__ == "__main__":
unittest.main()