从 MT2-AM8 模拟量模块迁移到 Easy521 PLC(Modbus TCP)

- 读取 D700(阀后流量)、D710(阀后压力)、D720(阀前压力),
  读用功能码 03,0~32000 线性映射到各自量程(300 SLM / 400 kPa / 300 kPa)
- 输出 D730(电机位置,0~10V),写用功能码 06,行程仍为 0~1000、死区 800
- 复用 MT2 骨架,保留 get_flow/get_pressure/set_motor_position 接口,
  channel 参数改为直接 Modbus 地址
- config.py 新增 PLC 设置,保留 MT2AM8 设置为死代码(MT2AM8Client 类保留)
- 同步更新 README.md 中的硬件接线、配置默认值与模块职责描述
This commit is contained in:
2026-09-01 17:03:26 +08:00
parent abab25326a
commit 5888b4ccce
10 changed files with 507 additions and 374 deletions
+17 -12
View File
@@ -173,7 +173,7 @@ def set_opening(hardware, opening_pct):
position = motor_position_for(opening)
if not hardware.set_motor_position(
position,
channel=config.MOTOR_OUTPUT_CHANNEL,
channel=config.MOTOR_OUTPUT_ADDR,
):
raise RuntimeError("电机位置写入失败")
return opening, position
@@ -184,11 +184,11 @@ def read_sensors(hardware, quiet=False):
output = io.StringIO()
stream = output if quiet else sys.stdout
with contextlib.redirect_stdout(stream):
flow = hardware.get_flow(config.FLOW_INPUT_CHANNEL)
flow = hardware.get_flow(config.FLOW_AFTER_ADDR)
pressure = (
None
if config.PRESSURE_INPUT_CHANNEL is None
else hardware.get_pressure(config.PRESSURE_INPUT_CHANNEL)
if config.PRESSURE_AFTER_ADDR is None
else hardware.get_pressure(config.PRESSURE_AFTER_ADDR)
)
return flow, pressure
@@ -199,17 +199,22 @@ def main():
return 1
try:
from PcControl import MT2AM8Client
from PcControl import Easy521ModbusClient
except ModuleNotFoundError as exc:
print(f"无法导入硬件客户端: {exc}")
return 2
hardware = MT2AM8Client(
host=config.MT2AM8_HOST,
port=config.MT2AM8_PORT,
slave_id=config.MT2AM8_SLAVE_ID,
pressure_range=config.PRESSURE_RANGE_KPA,
flow_range=config.FLOW_METER_RANGE_SLM,
hardware = Easy521ModbusClient(
host=config.PLC_HOST,
port=config.PLC_PORT,
slave_id=config.PLC_SLAVE_ID,
flow_addr=config.FLOW_AFTER_ADDR,
flow_range=config.FLOW_AFTER_RANGE_SLM,
pressure_before_addr=config.PRESSURE_BEFORE_ADDR,
pressure_before_range=config.PRESSURE_BEFORE_RANGE_KPA,
pressure_after_addr=config.PRESSURE_AFTER_ADDR,
pressure_after_range=config.PRESSURE_AFTER_RANGE_KPA,
motor_output_addr=config.MOTOR_OUTPUT_ADDR,
)
connected = False
@@ -222,7 +227,7 @@ def main():
try:
print(
f"正在连接 MT2-AM8 {config.MT2AM8_HOST}:{config.MT2AM8_PORT} ..."
f"正在连接 PLC {config.PLC_HOST}:{config.PLC_PORT} ..."
)
connected = bool(hardware.connect())